A centrifugal chiller utilizes the vapor compression cycle to chill water and reject this heat collected from the chilled water plus the heat from the compressor to a water loop cooled by a cooling tower.

A centrifugal chiller utilizes the vapor compression cycle to chill water and reject this heat collected from the chilled water plus the heat from the compressor to a water loop cooled by a cooling tower.

Image result for centrifugal chiller

Image result for centrifugal chiller

Evaporator 

The evaporator in a centrifugal water cooled chiller is usually a shell and tube heat exchanger that removes heat from the entering chilled water lowering its temperature in the process. The heat is used to boil the refrigerant changing it from a liquid to a gas. Chillers use a flooded type evaporator, which is very energy efficient. Flooded evaporators place the chilled water in the tubes and refrigerant in the shell completely submerging the tubes in refrigerant. Large chillers can have over five miles of tubing in their heat exchangers. 

Compressor

 The compressor assembly is made up of a prime mover and a centrifugal compressor. Chillers use liquid refrigerant cooled hermetic electric motors. The centrifugal compressor is a dynamic device similar to a centrifugal water pump. It raises the pressure and temperature of the refrigerant by converting kinetic energy into pressure. In this document we will refer only to centrifugal compressors. 

Condenser

 Like the evaporator, the condenser is usually a shell and tube heat exchanger. In this case, it removes heat from the refrigerant gas causing it to condense to a liquid. The heat raises the temperature of the cooling water often referred to as condenser water. The condenser water then carries the heat to the cooling tower where the heat is rejected to atmosphere.




Different type of Chiller Capacity, Specification and function with Details

Subscribe AfreenAli on YouTube 
Prepare By Syed M Afreen Ali (MSc / BS Engineering)


Reciprocating chiller: 

Reciprocating compressors are categorized as positive displacement machines. These are available in two basic types: hermetic sealed units and units of open construction. In hermetic sealed units, the motor and the compressor are direct-coupled and housed in a single casing that is sealed to the atmosphere. In open construction units, the motor and the compressor are in separate housings. In general, open construction units have a longer service life, lower maintenance requirements and higher operating efficiencies. The hermetic sealed units are most common particularly in small capacities. Single stage reciprocating machines have an ability to operate at compression ratios of 10 to 12. The capacity control in reciprocating machine is achieved through ‘On-Off’ or ‘LoadingUnloading’ of compressor cylinders. Reciprocating machines are manufactured in capacities from 0.5 to 150 TR. The main factors favoring reciprocating machine is low cost. The other advantage is that multiple reciprocating machines can be installed to closely match the building loads. Multiple units allow flexibility to operate machines per the need. If properly managed this could attribute to significant energy savings during low loads. A major drawback is a high level of maintenance requirement’s, noise and vibration. Since the capacity is limited to 150 TR, multiple units cost more than other options. Multiple chiller configurations require large space and consume more energy per ton of refrigeration. 
Image result for Reciprocating chiller:

Centrifugal Chillers

 Centrifugal chillers are categorized as variable volume displacement units. Like reciprocating machines these are also available in both hermetic and open construction. Commercially the hermetic sealed units are more widely used, despite its lower operating efficiency. Centrifugal chillers for refrigeration applications are generally designed for a fixed compression ratio of 18. The capacity control is achieved through the use of inlet vanes on the impellers that restrict refrigerant flow. The centrifugal chillers are manufactured in capacities from 90 to 2000 tons. The main factor favoring centrifugal machine is their high operational efficiency at full load, compact size and availability in large sizes. The biggest drawback of centrifugal machine is a very poor part load performance and inability to operate at low cooling loads. At extreme low loads, these chillers are prone to a condition known as surging. The main limitation is that these are not suitable for air-cooled condenser options and require water and cooling tower. 

Image result for Centrifugal Chillers


Screw Chillers 

Rotary or screw chillers, like reciprocating machines are positive displacement compressors. Rotary is a wider term that may include vane, eccentric, gear or screw types. The commercial refrigeration installation rely more on screw machines. Screw compressors are available in several designs, both single screw and twin screw, with oilfree and oil-injected designs in both types. Twin-screw oil-injected compressors are slightly more energy efficient at moderate compression ratios. Twin-screw compressors have an ability to operate at compression ratio of 30. Units are available in both hermetic sealed and open construction. The capacity control in screw compressor is achieved thorough a moveable slide stop valve, which will vary the compressor internal volume ratio to achieve optimum energy consumption during part load operation. Screw chillers are available in capacities ranging from 20 to 1000 tons and even higher from few manufacturers. The factors favoring screw chillers is their compact size, lightweight, quite & vibration free operation and high energy efficiency both in full and part load operation. The major drawback is their high cost. For smaller loads, reciprocating machines are less expensive to purchase and for large loads centrifugal machines cost less.

Image result for Screw Chillers

Scroll Chillers 

Scroll compressors have been used in commercial practice for systems that have capacity less than 30 TR. On such small sizes, these do not affect the life cycle economics drastically and therefore not discussed further. 

Image result for Scroll Chillers

OVERVIEW OF ROLE, RESPONSIBILITY& SCOPE OF MECHANICAL ELECTRICAL PLUMBING (MEP)

AfreenAli Subscribe on YouTube 


OVERVIEW OF ROLE, RESPONSIBILITY& SCOPE OF MECHANICAL ELECTRICAL PLUMBING (MEP) 


INTRODUCTION

 Mechanical Electrical Plumbing focus on mechanical drawing, mechanical drafting & design services with knowledge of Electrical and plumbing equipment. The Mechanical part of MEP is known as HVAC. It is responsible for the installation and maintenance of A.C heating and ventilation meaning changing fillers and installing furnace. It also involves Electrical parts for outlets and application but also lighting switches, fire alarm, security system,as well as lighting protection when necessary. The plumbing part also handles fine suppression system and storm pipe system as well as gas delivery system in Medical and laboratory setting. The Civil technologies deal of energy and water, along with sophistical and secure methods of delivery. Modern building requires substantial ventilation environmental control as well as safety precaution.


ROLE AND RESPONSIBILITY OF MEP ENGINEER 

MEP Engineer is a single –level professional classification responsible for planning and design in the area of Mechanical, Electrical and plumbing (MEP) system including developing policies standard, inspection procedure and evaluation tools for MEP matters involving judicial branch facilities, along with prepare, review drawing, specification and cost estimates for the mechanical, Electrical, and /or Plumbing. 
MEP Engineer has to develop best practice and maintenance management measure including the review and update of standard on a routine basic. 
MEP Engineer has to develops policies/review and standards for capital projects, facility database, and master plan information. 
MEP Engineer conduct engineering and feasibility and economics studies and prepare reports on finding develops standard for design and technical specification, investigates new MEP design concept and technical development of systems which are applicable to engineering problem. 
MEP engineer has to review plans and specification according to plan. 
MEP Engineer has to manages oversee the work of subordinate staff contact architects or Engineer. MEP Engineer has to prepare plans, details, specified and cost estimated of plumbing, heating, ventilating, air conditioning and general piping system. 
MEP Engineer has to provide technical advice to staff designer,supervisor,inspector and contracting service provider, regarding installation and maintenance of MEP System. 
MEP System has to analyze mechanical, Electrical and /or plumbing engineering problems and formulate solutions. 
MEP Engineer has to identify problems in design, plan, manage and deliver multiple projects. 
MEP Engineer has to plan, organize review and evaluate the work of consultant,contractor and others.
 MEP Engineer has to knowledge of MS office, AutoCAD and Project management software. 
MEP Engineer has to prepare and deliver effective oral presentation whenever required


What the mechanical engineers do?

AfreenAli Subscribe on YouTube


What the mechanical engineers do?

Mechanical engineers design power-producing machines, such as electric generators, internal combustion engines, and steam and gas turbines, as well as power-using machines, such as refrigeration and air-conditioning systems.Mechanical engineers design other machines, Plumbing, Fire Fighting inside buildings, such as elevators and escalators.

Being a mechanical engineer means applying the basic engineering principles and mechanical processes needed to create the machines and devices we use every day. Students discover concepts connected to thermodynamics, heat transfer, quality control and product design. There are also courses on materials used in the manufacturing processes. Practical learning happens through individual or team projects, which encourage students to apply their theoretical knowledge.

Friday, 24 May 2019

seamless Pipe VS ERW pipe




What is difference between seamless Pipe and ERW pipe?

A Seamless steel pipe is extruded and drawn from a billet whereas a welded (ERW) pipeis produced from a strip that is roll formed and welded (ERW )to produce a tube. Since aSeamless steel pipe offers a higher range of safety measures it is more expensive than a( ERW) welded tube.

What is meant by ERW pipe?

ERW pipes means Electric Resistance Welded Pipe. API 5L ERW pipes are used in various engineering purposes, fencing, scaffolding, line pipes etc. ERW pipes are available in various qualities, wall thicknesses, and diameters of the finished pipes. China Hua Yuan Steel Pipe is one of the best ERW Pipe manufacturer.

What does seamless pipe mean?

Seamless Pipe and Tube. Seamless pipe, as the name suggests, is a pipe without a seam or a weld-joint. Seamless Steel Pipe is made from a solid round steel 'billet' which is heated and pushed or pulled over a form until the steel is shaped into a hollow pipe.


Monday, 13 May 2019

Engineering Staff Required in Saudi Arabia

AfreenAli Subscribe in YouTube 


Engineering Staff Required in Saudi Arabia


A reputable international Contractor is looking for the following roles for their KSA operations on an urgent basis. All roles demand a prior experience in GCC.


If you are currently available in India and ready to join immediately, please send us your updated CV along with passport copy and all experience certificate copies on wepowerhr@gmail.com and richard.pegado@wepowerhr.com


1 Production supervisor/foremen 1no
Min. 10years experience in LSAW Plant
4000 - 5500 SR

2 QC engineer 1no
Min. 05years experience in LSAW Plant
4000 – 4500 SR

3 QA engineer 1no
Min. 05years experience in LSAW Plant
4000 – 4500 SR

4 Material receiving inspector 2nos
Previous QC experience
2000 – 3000 SR

5 Feeding inspector 1no
Previous QC experience
2000 – 3000 SR

6 MUT operator 2nos 
Saudi Aramco approved
3500 – 4500 SR

7 RTFI 2nos
Saudi Aramco approved
4500 SR – 5500 SR

8 Fluoroscopy 1no
NDT RT level 2
3500 – 4000 SR

9 Film placement helper 1no
With relevant experience 
2500 – 3000 SR

10 Yard & Shipment 1no
Min. 05years experience in QA
2000 – 3000 SR

11 Lab supervisor 1no
Min. 05years experience in QC lab(LSAW)
2500 – 3500 SR

12 Process controller 2nos
Min. 05years experience in QA (LSAW)
2500 – 3000 SR

13 Helpers 4nos
1700 – 2000 SR


14 Maintenance engineer 1no
Min. 10 years’ experience in LSAW Plant
4000 – 5500 SR

15 Fitters 2nos 
Min. 05 years’ experience in LSAW Plant Maint.
2000 – 3000 SR

16 Maintenance Technician 2nos
Min. 05 years’ experience in LSAW Plant Maint.
2500 – 3500SR

If you are currently available in India and ready to join immediately, please send us your updated CV along with passport copy and all experience certificate copies on wepowerhr@gmail.com and richard.pegado@wepowerhr.com


DRAFTSMAN ARCHITECT



A pioneer company & Consultant Office , has a vacancy of DRAFTSMAN Architect, having experience in consultant office for not less than TEN Years, preferable who have Saudi Exp.



Urgently required Safety Officer Osha/Iosh/Nebosh


We are looking for Safety Officer having experience with ARAMCO/SABIC Projects.
candidate must possess good Communication skills and must read/write/Speak English.

Max rate we can offer is Sar 27/hr
Appointment Duration: More than 1 year
Site accommodation, transportation & Food would be provided by Company.



Urgently required labor or helper.


We have very urgent requirement of Labor or Helpers. 

Salary : 1200 + 300 = 1500 Total Monthly.
Duty Hours : 8 Hours.
Over time ; 1.5 times.
Accommodation : Company provided.
Transportation : Company provided.
Medical : Insurance Card. 
All Other terms and conditions will be as per Saudi Labor Law.

Please contact :-  climatehvacr@gmail.com
0552710023
Haider Ali.


2 x Mechanical Inspector (urgent)


Required 2 Mechanical Inspectors as per below details

Required Education
High school diploma is a minimum. Knowledge and experience in Manufacturing Technologies are highly beneficial.

Required Skills
Expected to read and analyze blueprints, manuals etc.
Verify measurements of mechanical plans, and test the ascribed capabilities. 
Critical thinking skills, and proficiency with standard testing tools, calipers, depth gauge, microscope. 
Proficiency in English language is a must. Also, the use of computer.

Send CV at ta.ksajobs@gmail.com

Civil Engineer and Civil Foreman


We have urgently required below mentioned categories for our Riyadh Metro Project.
1- Civil Engineer having wet Finishing experience.
Work Experience more than 7 Years. 
2- Civil Foreman having wet finishing Experience more than 5 Years.

Interested Candidates send us resume one below mentioned email address and contact us.

email: amer.karanaljubail@gmail.com

Mobile No. 0591653051/ 0562167619

HVAC workers, multi-tasking


Have knowledge about repairing tools, good technical knowledge about plumbing, etc
Apply:-  jobs@alnakhla.sa




Tuesday, 16 April 2019

ASHRAE Standard and Google Drive MEP(HVAC , Plumbing, Fire Fighting and Electrical) complete Design Data and Drawings


ASHRAE Standard and Google Drive MEP(HVAC , Plumbing, Fire Fighting and Electrical) complete Design Data and Drawings
Subscribe on YouTube AfreenAli  
Prepare By S. M Afreen Ali (BS / MSc in Engineering)


ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) 

The American Society of Heating, Refrigerating and Air-Conditioning Engineers is a global professional association seeking to advance heating, ventilation, air conditioning and refrigeration systems design and construction.

Examples of some ASHRAE Standards are:
  • Standard 34 – Designation and Safety Classification of Refrigerants
  • Standard 55 – Thermal Environmental Conditions for Human Occupancy
  • Standard 62.1 – Ventilation for Acceptable Indoor Air Quality (versions: 2001 and earlier as "62", 2004 and beyond as "62.1")
  • Standard 62.2 – Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings
  • Standard 90.1 – Energy Standard for Buildings Except Low-Rise Residential Buildings – The IESNA is a joint sponsor of this standard.
  • Standard 135 – BACnet - A Data Communication Protocol for Building Automation and Control Networks
  • Standard 189.1 – Standard for the Design of High Performance, Green Buildings Except Low-Rise Residential Buildings


ANSI/ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy is an American National Standard published by ASHRAE that establishes the ranges of indoor environmental conditions to achieve acceptable thermal comfort for occupants of buildings.

If the temperature's between 70 and 80 degrees Fahrenheit and the relative humidity (RH) between 30% and 70%, we're more or less comfortable. Of course, the closer the humidity is to 70%, the lower the temperature needs to be for us to be comfortable.

The optimum room temperature is between 18°C and 21°C. Minimumtemperatures of 20°C or 21°C may be required for infants, the elderly and the sick.Temperatures lower than 18°C or higher than 24°C can be a health risk.

Every homeowner should own a hygrometer that measures temperature and relative humidity (RH). The ideal relative humidity for health and comfort is about 40–50%. In the winter months, it may have to be lower than 40% RH to avoid condensation on the windows.

The average atmospheric conditions, below which humans feel comfortably, are between 21 °C and 27.5 °C concerning air temperature; from 30 to 65%, for relative humidity; and wind speed values greater than 5 m/s

Along with standards, ASHRAE offers professional certifications. These include:
  • Building Commissioning Professional Certification: Skills to manage, plan and coordinate commissioning teams for new and existing buildings
  • Building Energy Assessment Professional Certification: Training to properly evaluate equipment for energy consumption and optimization
  • Building Energy Modeling Professional Certification: Ensures competency to assess and model building systems with the full range of physics, and apply software results to validate energy models
  • High-Performance Building Design Professional Certification: Training to generate sustainability models for high-performance buildings
  • Healthcare Facility Design Professional Certification: Information on incorporating standards and regulatory codes into HVAC system design for healthcare facilities
  • Operations and Performance Management Certification: Skills to effectively manage HVAC systems and achieve performance goals relating to air quality and safety
In 2018, professionals had earned more than 2,500 certifications to expand their industry knowledge and learn how to integrate ASHRAE standards into their everyday work.

Research

ASHRAE certification programs serve to reinforce that reputation. The Building Commissioning Professional (BCxP) and Building Energy Assessment Professional (BEAP) certifications have been recognized by the U.S. Department of Energy (DOE) as meeting the Better Buildings Workforce Guidelines (BBWG).

Google Drive MEP(HVAC , Plumbing, Fire Fighting and Electrical) complete Design Data and Drawings
Link is below ....

https://za.gl/LS2YOE
https://za.gl/LS2YOE